The MiniProx® proximity card reader’s potted electronics and slim, attractive design are ideal for indoor or outdoor mounting
- Available with either pigtail or terminal strip (terminal strip only for Hazardous Location version)
- Available with Wiegand or Clock-and-Data interface
- Potted reader suitable for indoor or outdoor use
- Hazardous Location version is UL 1604, Class I & II, Div. 2 and Class III listed
Key Features
- Accepts 5- to 16-volts, meeting most voltage requirements
- Available with Wiegand or Clock-and-data interface
- Allows easy upgrade from magstripe to a proximity reader; no rewiring or pulling of new cable required
- Offers high reliability, consistent read-range and low power consumption in an easy-to-install package
- Mounts directly onto metal with no change in read range performance
- Provides multicolor LED, compatibility with all standard access control systems and internal or host control of LED and beeper
-
Typical Maximum Read Range
ProxCard® II Card – up to 5.5″ (14 cm)
ISOProx® II Card – up to 5″ (12.7 cm)
DuoProx® II Card – up to 5″ (12.7 cm)
Smart ISOProx®/DuoProx® cards – up to 5″ (12.7 cm)
Proximity & MIFARE® Card – up to 5″ (12.7 cm)
ProxCard Plus® Card – up to 2″ (5.1 cm)
ProxKey® II Keyfob – up to 2″ (5.1 cm)
MicroProx® Tag – up to 2.5″ (6.4 cm)*Depending on local installation conditions
Dimensions
6.0″ x 1.7″ x 1.0″(15.2 x 4.3 x 2.54 cm)Power Supply
Standard MiniProx: 5-16 VDC
Haz. Loc. MiniProx: 5-16 VDC
Linear power supplies are recommendedCurrent Requirements
Average: 30 mA (5 VDC); 20 mA (12 VDC)
Peak: 110 mA (5 VDC); 110 mA (12 VDC)Operating Temperature
-22° to 150° F (-30° to 65° C)Operating Humidity
0-95% relative humidity non-condensingWeight
With terminal strip: 3.5 oz. (99 gm)
With pigtail: 3.8 oz. (108 gm)
Haz. Loc. MiniProx: 3.8 oz. (108 gm)Cable Distance
Wiegand interface: 500 feet (150 m)
Clock-and-data interface: 50 feet (15 m)
Recommended cable is ALPHA 1295 (22 AWG)
5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper controlCertifications
Canada/UL 294 Listed: Access Control System Units Canada/UL 1604 Listed (with Haz. Loc. junction box only): Hazardous Locations Class I, Div. 2, Groups A,B,C,D
FCC Certification, United States
Canada Certification
EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
Fifteen EU Countries under the R&TTE Directive (EN 300330 – SRD, and ETS 300 683 – EMC)
CE Mark
Australia C-Tick
New Zealand
Reviews
There are no reviews yet.